Engine Control Modules  Genaust 24V SPEED SENSOR UNIT PCB - G/A 383-S-009  |  | Engine Speed sensing unit with 3 adjustable levels and clean contact SPDT outputs. Sensing from either a magnetic pick up or 240Vac 50Hz. |
 Genaust Engine Control Unit - G/A ECU 384  |  | Used for the control and protection of stationary diesel engines with 4 safety shutdown inputs and 2 SPDT 10A clean contacts for switching fuel solenoids and starter motor solenoids. Safety inputs can be selected for N.C. or N.O. contact configuration.
|
 Genaust Engine Protection Unit - G/A EPU 390  |  | The EPU is designed tp protect diesel engines from damage caused by such things as overheating, overspeed, underspeed or loss of lubrication pressure. |
 Genaust Fuel Level Unit - G/A FLU 386  |  | Typically used for controlling the fuel level in a stationary diesel engine's fuel service tank. The level sensing medium is a commercially available float level resistance sender and the unit provides 4 adjustable levels. Two are used for transfer pump control while the others provide signals for low and empty fuel level. This unit is available in both 12V (Part No. FLU386-1) and 24V (Part No. FLU386-2) models. |
 Genaust Speed Sensing Unit - G/A SSU 383  |  | Engine Speed sensing unit with 3 adjustable levels and clean contact SPDT outputs. Sensing from either a magnetic pick up or 240Vac 50Hz. |
 Genaust Synch Check Unit - G/A SCU 387  |  | This Unit is a simple in synchronism check unit to prevent two D/A sets from being paralleled incorrectly. |
 Genaust TIMING & SENSING UNIT - G/A TSU 389  |  | Intended for use as a standby D/A set sensing and start timing unit. Has inbuilt/onboard adjustable timers for Delay start, 3 repeat cranking, Delay supply return and Delay engine stop or cool down period. Allows either 3 phase or single phase normal mains supply to be monitored as well as single phase standby supply. Also provides output signals for transfer switch control, crank periods and engine start/stop. Interfacing with a hybrid system comprising of say an inverter and storage battery bank is possible with an onboard selector switch. Provision for remote start, stop, test and lockout signals are also included. |
 Genaust Voltage Sensing Unit - G/A VSU 385  |  | Designed to monitor 3Ø normal mains supply voltage as well as 1Ø standby voltage. Has on board relays to give clean contact outputs for standby start initiation and standby load acceptance. Senses both over and under volts for each supply as well as phase differential on the 3Ø mains sensing inputs. | |