Product Search:
Power Drive Systems

Relays & Meters

Rhomberg RHOMBERG RELAY BASE - RHO S3-B     
An 11 pin base suitable for Rhomberg 'SP' range of relays
Rhomberg CURRENT MONITOR AC 1 PHASE - RHO P100P     
Features
  • DIN rail mount.
  • Fail-to-safe design.
  • Interchangeable plug-in power supply (up to 240VAC).
  • Programmable for overload or underload monitoring.
  • 1A, 2A or 5A, AC or DC input range (programmable).
  • Internal shunt for direct in-line current sensing (max 5A AC or DC).
  • Direct interface with conventional current transformers for >5A.
  • Trip point adjustable on percentage scale (10% to 100%).
  • Adjustable hysteresis (5% to 30%).
  • Adjustable response time available on trip and recovery (0.1 to 10 seconds).
  • Start-up delay 10 sec fixed.
  • Selectable latching (ie manual or auto reset).
  • Power ON & Relay ON LED's.
  • 10A SPDT relay output.

Click here for technical manual (PDF 101k)

Rhomberg VOLTAGE MONITORING RELAY SINGLE PHASE AC(rms)/DC - RHO P200P     
Features
  • DIN rail mount.
  • Fail-to-safe design.
  • Interchangeable plug-in power supply (up to 240V).
  • Programmable for overvoltage or undervoltage monitoring.
  • Programmable input voltage range up to 600V AC (RMS) or DC (Input ranges: (AC or DC), 15V 150V, 30V 300V, 60V 600V).
  • Trip point adjustable on percentage scale (10% to 100%).
  • Adjustable hysteresis (5% to 30%).
  • Adjustable response time available on trip and recovery (0.1 to 10 seconds).
  • Selectable latching (ie manual or auto reset).
  • Power ON & Relay ON LED's.
  • 10A SPDT relay output.

Click here for technical manual (PDF 103k)

Rhomberg VOLTAGE WINDOW COMPAR. ADJ.T&R - RHO P230P     
Features
  • DIN rail mount.
  • Fail-to-safe design.
  • Combined overvoltage and undervoltage monitoring.
  • Monitoring of own supply voltage (3 phase).
  • Separately adjustable setpoints: over-voltage, (5 to 20%) and, under-voltage (-5 to -20%).
  • Adjustable response time available on trip and recovery (0.1 to 10 seconds).
  • Fixed hysteresis: 2%.
  • Adjustable start-up delay for disabling latching 0 to 10 sec.
  • Selectable latching (ie manual or auto reset).
  • LED indication of Power ON, Relay ON and fault type.
  • 10A SPDT relay output.

Click here for technical manual (PDF 106k)

Rhomberg CURRENT WINDOW COMPARATOR - RHO SP123     
Features
  • 11-pin plug-in.
  • Fail-to-safe design.
  • Adjustable time delay on trip 0.1 to 10 seconds.
  • Combined overload and underload detection.
  • 1A or 5A, AC input range (programmable).
  • Internal shunt for direct in-line current sensing (AC).
  • Direct interface with conventional current transformers.
  • Fixed hysteresis: 2%.
  • Separate adjustment of overload and underload setpoints.
  • Adjustable response time on trip (0.1 to 10 seconds).
  • Start-up delay 10 sec fixed.
  • Selectable latching (ie manual or auto reset).
  • LED indication of Relay ON and fault type.
  • 10A SPDT relay output.
  • Supercedes SP120

Click here for technical manual (PDF 110k)

Rhomberg FREQUENCY MONITOR - RHO SP320     
Features
  • 11-pin plug-in.
  • Fail-to-safe design.
  • Selectable: Over-frequency, Under-frequency or Frequency Window Monitoring
  • Start-up delay: 0 sec or 10 sec (selectable)
  • Separately adjustable setpoints: over-frequency, (52 to 58 Hz), Under-voltage (42 to 48Hz).
  • 60Hz & 400Hz nominal frequency versions available on request.
  • Fixed hysteresis: 0.5Hz
  • LED indication of Power ON, Relay ON, over frequency & under frequency.
  • 10A SPDT relay output.

Click here for technical manual (PDF 109k)

Rhomberg PHASE SEQ/FAIL DETECTOR - RHO SP430     
Features
  • 11-pin plug-in.
  • Fail-to-safe design.
  • Monitoring on three phase supply.
  • Sensitive to: NPS Voltage, Reverse phase sequence, loss of phase, phase imbalance, phase asymmetry.
  • Insensitive to regenerated EMF.
  • High stability under harmonic distortion
  • Insensitive to balanced supply variations - prevents nuisance tripping
  • Fast response to reversed phase sequence
  • Adjustable NPS sensitivity.
  • Relay ON LED
  • 10A SPDT or 5A DPDT relay output.

Click here for technical manual (PDF 104k)

Rhomberg VOLTAGE MONITOR 1-PHASE - RHO SP201     
Features
  • 11-pin plug-in.
  • Fail-to-safe design.
  • Programmable for overvoltage or undervoltage monitoring.
  • Programmable input voltage range up to 600V AC (RMS) or DC (Input ranges: (AC or DC), 15V 150V, 30V 300V, 60V 600V).
  • Trip point adjustable on percentage scale (10% to 100%).
  • Adjustable hysteresis (5% to 30%).
  • Adjustable response time on trip (0.1 to 10 seconds).
  • Selectable latching (ie manual or auto reset).
  • Relay ON LED's.
  • 10A SPDT relay output.
  • Supercedes SP200.

Click here for technical manual (PDF 107k)

Rhomberg VOLTAGE WIN COMP 3PHASE - RHO SP231     
Features
  • 11-pin plug-in.
  • Fail-to-safe design.
  • Combined overvoltage and undervoltage monitoring.
  • Monitoring of own supply voltage (3 phase).
  • Separately adjustable setpoints: over-voltage, (5 to 20%) and, under-voltage (-5 to -20%).
  • Adjustable response time on trip (0.1 to 10 seconds).
  • Fixed hysteresis: 2%.
  • Fixed start-up delay for disabling latching 10 sec.
  • Selectable latching (ie manual or auto reset).
  • LED indication of Relay ON and fault type.
  • 10A SPDT relay output.
  • Supercedes SP230.

Click here for technical manual (PDF 113k)

Rhomberg VOLTAGE WINDOW COMPARITOR 240v - RHO SP221     
Features
  • 11-pin plug-in.
  • Fail-to-safe design.
  • Combined overvoltage and undervoltage monitoring.
  • Monitoring of own supply voltage (single phase).
  • Separately adjustable setpoints: over-voltage, (5 to 20%) and, under-voltage (-5 to -20%).
  • Adjustable response time on trip (0.1 to 10 seconds).
  • Fixed hysteresis: 2%.
  • Fixed start-up delay for disabling latching 10 sec.
  • Selectable latching (ie manual or auto reset).
  • LED indication of Relay ON and fault type.
  • 10A SPDT relay output.
  • Supercedes SP220.

Click here for technical manual (PDF 106k)

Rhomberg MULTI-FUNCTION TIMER 0.1S-100HR - RHO 48T101     
Features
  • 8-pin plug-in.
  • Time settings 0.1 sec to 100 hours
  • Extra short body
  • Test mode in all ranges
  • Automatic (ie power up) start
  • Power ON and Relay ON LEDs
  • Flashing Power ON LED when unit is timing.
  • DPDT (5A per contact)
  • Plug-in replacement for other brands
  • Includes panel mount bezel (not shown in photo)

Click here for technical manual (PDF 262k)

123next >>
[home] [voltage regulators] [control modules] [monitoring relays] [ups systems] [battery chargers] [governors] [technical data] [downloads] [about us] [contact us]
Email: sales@powersystems.com.au
Phone: +61 7 3350 4594
Fax: +61 7 3350 1654
Dynamic Internet Web Hosting Brisbane James Hamilton Electrical Pty Ltd
ABN 56 010 848 389
Trading as Power Drive Systems